Determination of Creatinine in Urine by Voltammetry and Glassy Carbon Electrode Modified with Functionalized Multi-walled Carbon Nanotubes and Copper
dc.contributor.author | Pedrozo-Penafiel M.J. | |
dc.contributor.author | Lopes T. | |
dc.contributor.author | Gutierrez-Beleno L.M. | |
dc.contributor.author | Miranda-Andrades J.R. | |
dc.contributor.author | Maia Da Costa M.E.H. | |
dc.contributor.author | Larrude D.G. | |
dc.contributor.author | Aucelio R.Q. | |
dc.date.accessioned | 2024-03-12T19:10:28Z | |
dc.date.available | 2024-03-12T19:10:28Z | |
dc.date.issued | 2023 | |
dc.description.abstract | © 2022 Wiley-VCH GmbH.A square-wave voltammetric method was developed for the determination of creatinine using glassy carbon electrode functionalized multi-walled carbon nanotubes and doped with copper. Since the creatine-creatinine balance is dependent on pH, the linear responses at either pH 4.0 or 7.0 were evaluated allowing versatility in application, covering analyte concentration from limit of quantification (0.3 μmol L−1) up to 1.200 μmol L−1 (pH 4) or 660 μmol L−1 (pH 7). Electrode is simple to prepare and robust for routine analysis and it was used for the determination of creatinine in urine after simple thin-layer separation procedure to avoid interference from creatine. | |
dc.description.issuenumber | 2 | |
dc.description.volume | 35 | |
dc.identifier.doi | 10.1002/elan.202200081 | |
dc.identifier.issn | 1521-4109 | |
dc.identifier.uri | https://dspace.mackenzie.br/handle/10899/34122 | |
dc.relation.ispartof | Electroanalysis | |
dc.rights | Acesso Restrito | |
dc.subject.otherlanguage | Creatinine | |
dc.subject.otherlanguage | f-MWCNT | |
dc.subject.otherlanguage | Square-wave voltammetry | |
dc.subject.otherlanguage | urine analysis | |
dc.title | Determination of Creatinine in Urine by Voltammetry and Glassy Carbon Electrode Modified with Functionalized Multi-walled Carbon Nanotubes and Copper | |
dc.type | Artigo | |
local.scopus.citations | 0 | |
local.scopus.eid | 2-s2.0-85133932716 | |
local.scopus.subject | F-MWCNT | |
local.scopus.subject | Functionalized multi-walled carbon nanotubes | |
local.scopus.subject | Glassy carbon electrodes | |
local.scopus.subject | Linear response | |
local.scopus.subject | MWCNT's | |
local.scopus.subject | Simple++ | |
local.scopus.subject | Square wave voltammetry | |
local.scopus.subject | Square-wave | |
local.scopus.subject | Urine analysis | |
local.scopus.subject | Voltammetric methods | |
local.scopus.updated | 2024-10-01 | |
local.scopus.url | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85133932716&origin=inward |